Coolant:Water
Primary system volume:0.67 m3
Primary system pressure (max):7.4 MPa
Core flow area:0.0116 m2
Nb jet pumps:2
Nb recirculation loops:2
Scaling method:P-to-V(Kv)
Time scale:1
Volumetric scale:1/624
Height scale:1
Scaling approaches:
Number of sim. fuel Rods:64
Diameter:12.3 mm
Pitch:16.2 mm
Heated length:4.14 m
Max power:7 MW
Axial Peaking factor:1.4
Heating method:Skin
Axial power distribution:Chopped cosine
FIST/6SB2C, BWR/6 Recirculation Suction Line Break Test
FIST/6MSB1, BWR/6 Main Steamline Double-Ended Break Test
FIST/6SB1, BWR/6 Simulated Recirculation Line Break
FIST/6PMC1, BWR/6-128 Isolation Valve (MSIV) Closure without Power Scram
FIST/6IB1, BWR/6 System Responses to Intermediate Break in Recirculation Suction Line LINE
FIST/4DBA1, BWR/4-218 Simulated Double-Ended Large Break Test
FIST/T1QUV, Simulated Failure to Maintain Water Level in BWR/6-218
FIST/T23C, Simulated Failure to Maintain Water Level in BWR/6-218
A G Stephens: FIST Facility Description Report, NUREG/CR-2576, EPRI NP-2314, GEAP- 222054, December 1982
https://inis.iaea.org/collection/NCLCollectionStore/_Public/16/031/16031275.pdf
J E Thompson: BWR Full Integral Simulation Test (FIST) Program Test Plan, NUREG/CR-2575, EPRI-NP-2313, GEAP-22053, April1982
https://inis.iaea.org/search/searchsinglerecord.aspx?recordsFor=SingleRecord&RN=14761379
W S Hwang, Md. Alamgir, W A Sutherland: BWR Full Integral· Simulation Test (FIST) Phase 1 Test Results, NUREG/CR 3711, EPRI NP-3602, GEAP-30496, 1983
W A Sutherland, Md. Almgir, J A Findlay, W S Hwang: BWR - Full integral Simulation Test (FIST) Phase ll, Test Results and TRAC-BWR Model Qualification, NUREG CR-4128
https://inis.iaea.org/collection/NCLCollectionStore/_Public/17/032/17032627.pdf