Height scale:1
Test details:
Performance 1. - Introduction of water into the U-tube up to a certain level - Start of the blower and introduction of a defined air flow rate. - Start of data acquisition - Waiting until variations of the resulting flow pattern are diminished - Blower turnoff and performance of measurements Performance 2. - Start of the blower and establishing a defined air flow rate. - Introduction of water at the bottom of the horizontal U-tube section until water entrainment is observed. - Waiting until the entrainment stops. - Measurement of data. - Blower turnoff and conductance of further measurements.
Pressure min:0.101 MPa
Pressure max:0.101 MPa
Temperature min:20 °C
Temperature max:20 °C
Keywords General:
Keywords Others:
Components details:
Comparative Assessment of ATHLET and CATHARE Two Phase Stratified Flow Models by means of the ECTHOR Loop Seal Tests
Schaffrath, A, et al., ATHLET code verification by ECTHOR loop seal experiment
Verification of the two-phase stratified-flow model in athlet by separate effect tests
https://www.sciencedirect.com/science/article/pii/0029549394008967
Framatome Report EP/TA/DC/533, June 1985.
Relevance | Phenomenon |
---|---|
Counter Current Flow Limitation (CCFL) | |
Loop Seal Phenomena (CL) | |
Stratification in horizontal pipes |