Pressure max:3 MPa
Experimental details:
All the tests were conducted under a mixed inlet condition, i. e. a condition where steam-water two-phase mixture enters the test section inlet. The test conditions covered ranges of pressure of 3 MPa, mass flux from 105 to 320 kg/m2 • s and inlet quality from 0.15 to 0.90.
Keywords General:
Keywords Steam Separator:
Test section details:
The test section consists of an entrance region of 1,600±5 mm length and a heating region of 2,000 ± 15 mm length. The test section is composed of a SUS 304 outer pipe of 30 mm 0. D. and 22±0.1 mm I. D., and an inner heater rod of 12.27 ±0.05 mm 0. D. The inner heater rod consists of three regions : non-heated entrance region of 1,600±5 mm length, heated region of 2,000± 15 mm length and non-heated outlet region of 500±2 mm length.
J. Nucl. Sci. Tech. 21, 965-968, Investigation of Pre-and Post-Dryout Heat Transfer in Upward Steam-Water Two-Phase Flow at Low Flow Rate with Improved Surface Temperature Measurement, 1984
https://www.tandfonline.com/doi/abs/10.1080/18811248.1984.9731141
Nucl. Engg. Design, 99, 157-165, Post-dryout heat transfer of high-pressure steam-water two-phase flow in single rod channel and multi rod bundle, 1987
https://www.sciencedirect.com/science/article/pii/0029549387901178
J. Nucl. Sci. Technol. 27, 68-80, Critical Heat Flux for Annulus under High-Pressure, Low-Flow and Mixed Inlet Conditions, 1990
https://www.tandfonline.com/doi/abs/10.1080/18811248.1990.9731153
Relevance | Phenomenon |
---|---|
Entrainment and Deentainment | |
Heat Transfer : SG | |
Phase separation | |
Quench Phenomena |