Number of simulated fuel rods:126
Pressure min:0.101 MPa
Pressure max:0.101 MPa
Temperature min:20 °C
Temperature max:20 °C
Keywords Core:
Keywords Others:
I. Kokkonen, Air/Water Counter Current Flow Limitation Experiments with Full-Scale Full Bundle Structures, IV0-A-07/89, October 1989
IVO-THERMAL MIXING, study mixing of emergency cooling water with primary water during LOCA accident
IVO-Loop Seal Facility (Air/Water), Two-phase behaviour of a PWR cold leg loop seal during LOCA accidents
IVO/AIR-WATER-CCFL, Air/water countercurrent flow limitation experiments with full-scale fuel bundle structures
H. Tuomisto, Nucl. Eng. Design 102, 171- 176, Large-scale air/water flow tests for separate effects during LOCAs in PWRs, 1987
https://www.sciencedirect.com/science/article/pii/0029549387902494
S. G. Bankoff, et al, "Countercurrent Flow of Air/Water and Steam/Water Through a Horizontal Perforated Plate," Int. J Heat and Mass Transfer, Volume 24, pp. 1381-1395, 1981.
https://www.sciencedirect.com/science/article/pii/0017931081901885
C. L. Tien, K. S. Chung, and C. P. Liu, "Flooding in Two-Phase Countercurrent Flows," EPRI NP-1283, December 1979.
https://inis.iaea.org/search/searchsinglerecord.aspx?recordsFor=SingleRecord&RN=11552441
Relevance | Phenomenon |
---|---|
Counter Current Flow Limitation (CCFL) | |
Phase separation |