Pressure min:5 MPa
Pressure max:5 MPa
Keywords Core:
Keywords Others:
The Marviken Full Scale Critical Flow Tests. Conclusions. Joint Reactor Safety Experiments in the marviken Power Station, Sweden. MXC-402. December 1979
L. Sokolowski, T. Kozlowski, Assessment of Two-Phase Critical Flow Models Performance in RELAP5 and TRACE Against Marviken Critical Flow Tests, MXC-301, Dec. 1979
Marviken Full Scale Critical Flow Tests Volume 10. Results of Test 2. EPRl-NP-2370, Vol. 10, May 1983
Marviken Full Scale Critical Flow Tests Volume 12. Results of Test 4. EPRl-NP-2370, Vol. 12, May 1983
Marviken Full Scale Critical Flow Tests Volume 17. Results of Test 9. EPRl-NP-2370, Vol. 17, May 1983
Marviken Full Scale Critical Flow Tests Volume 21. Results of Test 13. EPRl-NP-2370, Vol. 21, May 1983
Marviken Full Scale Critical Flow Tests Volume 28. Results of Test 20. EPRl-NP-2370, Vol. 28, May 1983
Marviken Full Scale Critical Flow Tests Volume 31. Results of Test 23. EPRl-NP-2370, Vol. 31, May 1983
Marviken Full Scale Jet Impingement Tests, Facility Description, MXD-101, February 1982
Marviken Full Scale Jet Impingement Tests, Test 5 Results, MXD-205, December 1981
The Marviken Full Scale Jet Impingement Tests. Summary Report, Sweden. MXD-301, Mar 1982
Marviken Full Scale Jet Impingement Tests, Test 11 Results, MXD-211, March 1982
MARVIKEN-FSCB-I, Marviken Full Scale Containment Blowdown experiments Series I
MARVIKEN-FSCB-II, Marviken Full Scale Containment Blowdown experiments Series II
MARVIKEN-ATT, Marviken Aerosol Transport Test experiments
MARVIKEN-CFT, Marviken Full Scale Critical Flow Tests
MARVIKEN-JIT, Marviken Full Scale Jet Impingement Tests experiments
Grolmes, M.A. and Sharon, A. Level Swell Analysis of the Marviken Test T-11. Nucl. Sci. Eng., 93, (1986) p. 229-239
Siemens AG UB KWU, U9 316/89/2 Quick Look Report - UPTF - Test No. 6, Downcomer Countercurrent Flow Test, March 1989.
Siemens AG UB KWU, U9 316/88/18, Experimental Data Report - UPTF - Test No. 6, Downcomer Countercurrent Flow Test, March 1989.
Siemens AG KWU, E314/90/003, Quick Look Report - UPTF - Test No. 7, Downcomer Countercurrent Flow Test, March 1990.
Siemens AG KWU, NT31/99/06, Quick Look Report - UPTF - Test No. 10, Phase C, Run 082, Tie Plate Countercurrent Flow Test, March 1999.
Siemens AG KWU, U9 316/88/1, Experimental Data Report - UPTF - Test No. 10, Tie Plate Countercurrent Flow Test, February 1988.
Siemens AG KWU, E314/90/05, Experimental Data Report - UPTF - Test No. 29, Entrainment/Deentrainment, June 1990
"The Marviken Full Scale Containment Experiments" Summary report MXA-301, MXA-402, MXB-301, MXB-402. Studsvik Energinteknik AB, Sweden, December 1974 and March 1977
The Marviken Full Scale Critical Flow Tests
Relevance | Phenomenon |
---|---|
Break Flow | |
Flashing | |
Phase separation |