Number of simulated fuel rods:33
Heat method:Indirect
Pressure min:0.1 MPa
Pressure max:0.5 MPa
Power min:24.6 kW
Power max:75.1 kW
Keywords General:
Keywords Core:
Keywords Steam Separator:
S. N. Aksan, F. Sierli, G. Th. Analytis, Boil-off experiments with the EIR-NEPTUN Facility: Analysis and code assessment overview report, EIR-Bericht Nr.629, 1987
N. Aksan, F. Stierli, G. Th. Analytis: "Boil-off experiments with the EIR-NEPTUN facililty: Analysis and code assessment overview report". NUREG/IA-0040 (EIR report No. 629), 1992. (Nuclear Engineering and Design 143 (245-264), 1993).
NEPTUN/5007, PWR LOCA Cooling Heat Transfer Tests for Loft, Boil-Off Experiments
NEPTUN/5050, PWR LOCA Cooling Heat Transfer Tests for Loft, Reflood Test
NEPTUN/5052, PWR LOCA Cooling Heat Transfer Tests for Loft, Reflood Test
Relevance | Phenomenon |
---|---|
Entrainment and Deentainment | |
Heat Transfer : Core | |
Heat Transfer : SG | |
Phase separation |