Program name | Package id | Status | Status date |
---|---|---|---|
ZZ-UNGER | DLC-0164/01 | Tested | 22-MAR-1994 |
Machines used:
Package ID | Orig. computer | Test computer |
---|---|---|
DLC-0164/01 | IBM PC | PC-80486 |
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
FORMAT: special format defined in documentation
NUMBER OF GROUPS: --
NUCLIDES: Be, C, N, O, F, Na, Mg, Al, Si, Cl, Ar, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo, Tc, Ru, Rh, Pd, Ag, Cd, In, Sn, Sb, Te, I, Xe, Cs, Ba, La, Ce, Pr, Nd, Pm, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb, Bi, Po, At, Rn, Fr, Ra, Ac, Th, Pa, U, Np, Pu, Am, Cm, Bk, Cf, Es, Fm.
ORIGIN: DLC-80/DRALIST and ANSI/ANS-6.1.1-1991
WEIGHTING SPECTRUM: --
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
ZZ-UNGER is a data set of gamma-ray fluence-to-effective dose factors and specific dose constants for nuclides important to dosimetry and radiological assessments.
The data are used to assess the radiological hazard of the various radionuclides from the unshielded dose rate at 1 meter (the specific dose constant).
The fluence-to-dose factors of ANS-6.1.1 are applied to the gamma-ray intensity for each energy of each nuclide of the Kocher compilation (DLC-80) and summed to give the total anterior-posterior (AP) factors and specific dose constants. Gamma rays of less than 10 KeV were neglected. The results are compared to the results of the 1982 publication.
ZZ-UNGER is an update to ORNL/RSIC-45/R1 (1982) based on DLC-80/DRALIST radioactive decay spectra and ANSI/ANS-6.1.1--1991 fluence-to-dose factors. ORNL/RSIC-45/R1 was based on the fluence-to-dose factors of ANSI/ANS-6.1.1--1977.
There is no retrieval program. However, the program for calculating the dose factors and specific dose constants, implemented on a PC using the Microsoft 5.0 compiler, is included.
American National Standard Neutron and Gamma-Ray Fluence-to-Dose Factors ANSI/ANS-6.1.1--1991, American Nuclear Society, La Grange Park, IL 60525.
File name | File description | Records |
---|---|---|
DLC0164_01.001 | ZZ-UNGER.INF ZZ-UNGER Information file | 95 |
DLC0164_01.002 | NOTES.DOC Explanatory notes on prog. UNGER | 113 |
DLC0164_01.003 | UNGER.FOR UNGER Source code file | 290 |
DLC0164_01.004 | MAKUNGER.BAT Batch file to gen. UNGER.EXE | 19 |
DLC0164_01.005 | UNGER.EXE UNGER Executable file | 0 |
DLC0164_01.006 | DRALIST.DAT Lib of input data to run UNGER | 8201 |
DLC0164_01.007 | GAMDCF2.OUT Fluence-to-dose conv.fac.outpt. | 2776 |
DLC0164_01.008 | GAMDCF3.OUT Eff. dose conv. factor output | 917 |
DLC0164_01.009 | DOS file-names | 8 |
Keywords: dose rates, gamma radiation.